Authorized Yixist Distributor · Malaysia

Yixist Spectrometer Systems

TFL Solutions is the authorized distributor for Yixist spectrometers in Malaysia. From miniature USB spectrometers to scientific-grade TE-cooled systems and portable Raman analyzers — spanning 180 nm to 2500 nm.

Request a QuoteYixist Website ↗
λ/Δλ up to 10,000 180 – 2500 nm · UV · VIS · NIR · Raman
TFL Solutions × YIXIST

Authorized Distributor for Yixist Technology in Malaysia

TFL Solutions is the authorized representative for Yixist Technology Co., Ltd in Malaysia — a leading spectrometer manufacturer with over 20 years of experience in optical engineering. All Yixist products are supplied with full manufacturer warranty, calibration certificate, and software. Contact TFL for pricing, demonstrations, and technical support.

YSM-8101 UV-VIS Miniature by Yixist
UV-VIS Miniature · YSM-8101 Series
Miniature UV-VIS Spectrometers

Business-card-sized optical platform with USB connectivity. Lightweight and portable, the YSM-8101 series is an economical choice for spectral measurements in scientific and industrial applications. Customizable wavelength range and resolution available.

View on Yixist.com
YSM-8101 Series
YSM-8101-01
200 – 1100 nm (customizable)
  • Miniature business-card size platform
  • Optical resolution: 0.35 – 5 nm (0.35–1 nm typical)
  • Dynamic range: 300:1
  • Interface: RS232 / RS422 / USB
  • SDK + deep customization supported
  • Trigger mode available
  • Economical option for general spectral work
Enquire
YSM-8101 Series ★ Popular
YSM-8101-02
180 – 1100 nm (customizable)
  • Detector: Hamamatsu S11639 (enhanced sensitivity)
  • Optical resolution: 0.35 – 5 nm
  • Dynamic range: 10,000:1
  • S/N ratio: 600:1
  • Min. integration time: 0.5 ms
  • Interface: RS232 / RS422 / USB
  • Enhanced anti-interference design
  • Suitable for industrial and scientific use
Enquire
ParameterYSM-8101-01YSM-8101-02
Wavelength Range200–1100 nm (custom)180–1100 nm (custom)
Optical Resolution0.35–5 nm0.35–5 nm
Dynamic Range300:110,000:1
S/N Ratio600:1
Min. Integration TimeCustom0.5 ms
DetectorLinear CCDHamamatsu S11639
InterfaceRS232/RS422/USBRS232/RS422/USB
SDK / OEM
YSM-8102 UV-VIS High-Res by Yixist
UV-VIS High Resolution · YSM-8102 Series
High-Resolution UV-VIS Spectrometers

High-resolution optical-mechanical platform with up to 0.06 nm optical resolution. Alterable gratings and slits provide flexibility across spectral ranges and resolutions. Ideal for laser characterisation, Raman pre-processing, and narrow-linewidth spectral analysis.

View on Yixist.com
YSM-8102 Series
YSM-8102-01
315 – 1100 nm
  • Detector: TOSHIBA TCD1304 linear CCD
  • Optical resolution: 0.06 – 0.3 nm
  • High-resolution optical-mechanical platform
  • Lightweight and compact form factor
  • USB interface · SDK available
  • Alterable gratings for different ranges
  • Operating temperature: 5 – 35 °C
Enquire
YSM-8102 Series ★ Popular
YSM-8102-03
200 – 1100 nm
  • Detector: Hamamatsu S16010 2048×64 area array CCD
  • Optical resolution: up to 0.1 nm
  • S/N ratio: up to 800:1
  • Dynamic range: 50,000:1
  • High sensitivity in 700–1100 nm range
  • Alterable gratings + slits for Raman/custom use
  • RS232 / trigger / SDK supported
Enquire
ParameterYSM-8102-01YSM-8102-03
Wavelength Range315–1100 nm200–1100 nm
Optical Resolution0.06–0.3 nmup to 0.1 nm
DetectorToshiba TCD1304HAM S16010 2048×64 CCD
S/N Ratioup to 800:1
Dynamic Range50,000:1
Best Sensitivity Band315–1100 nm700–1100 nm
InterfaceUSBRS232/USB/Trigger
Alterable Gratings
YSM-8103 UV-VIS Area Array by Yixist
UV-VIS Area Array · YSM-8103 Series
UV-VIS Area Array CCD Spectrometers

Hamamatsu back-illuminated area array CCD detectors with UV-sensitive or IR-sensitive options. Dynamic range up to 50,000:1. Available in UV-enhanced and NIR-enhanced variants — suitable for water quality, gas analysis, fluorescence, and Raman measurements.

View on Yixist.com
YSM-8103 Series · NIR-sensitive
YSM-8103-03
200 – 1100 nm
  • Detector: Hamamatsu S16010 2048×64 CCD (IR-sensitive)
  • Enhanced sensitivity: 700–1100 nm band
  • Dynamic range: up to 50,000:1
  • RS232, Trigger modes, SDK available
  • Deep OEM customization supported
  • Ideal for fluorescence and Raman
  • Customizable grating and wavelength range
Enquire
YSM-8103 Series · UV-enhanced ★
YSM-8103-04
200 – 1100 nm
  • Detector: Hamamatsu S10420 2048×64 CCD (UV-sensitive)
  • Enhanced sensitivity: 200–500 nm UV band
  • Dynamic range: up to 50,000:1 (typical)
  • RS232, Trigger modes, SDK available
  • Water quality and gas monitoring optimised
  • Suitable for fluorescence spectral measurement
  • Multiple grating options for resolution adjustment
Enquire
ParameterYSM-8103-03YSM-8103-04
Wavelength Range200–1100 nm (custom)200–1100 nm (custom)
DetectorHAM S16010 (IR-sensitive)HAM S10420 (UV-sensitive)
Detector Pixels2048 × 642048 × 64
Enhanced Band700–1100 nm200–500 nm
Dynamic Range50,000:150,000:1
InterfaceRS232/USB/TriggerRS232/USB/Trigger
Best ForFluorescence, RamanWater quality, gas, UV fluorescence
YSM-8104 UV-VIS TE-Cooling by Yixist
UV-VIS TE-Cooling · YSM-8104 Series
Scientific-Grade TE-Cooled Spectrometers

Research-grade thermoelectrically cooled CCD detectors from Hamamatsu with 18-bit A/D conversion. Optimised low-noise circuits and CT optical structure deliver exceptional S/N ratios for demanding Raman and fluorescence spectroscopy.

View on Yixist.com
YSM-8104 Series
YSM-8104-07
200 – 1100 nm (customizable)
  • Detector: Hamamatsu S7031-1006s 1024×58 TE-cooled CCD
  • Research-grade sensitivity
  • 18-bit A/D converter
  • CT optical structure (improved stability)
  • Low-noise circuit design
  • Excellent for Raman and fluorescence
  • SDK / USB / RS232 / GPIB interfaces
Enquire
YSM-8104 Series · Scientific ★
YSM-8104-08
200 – 1100 nm
  • Detector: Hamamatsu S10141-1107S-01 2048×122 TE-cooled CCD
  • Back-illuminated; pixel size 12×12 µm
  • 18-bit A/D converter; extremely low noise
  • CT optical structure for high thermal stability
  • Excellent S/N and sensitivity for weak signals
  • Suitable for Raman, fluorescence, complex spectroscopy
  • SDK / USB / RS232 / trigger interfaces
Enquire
ParameterYSM-8104-07YSM-8104-08
Wavelength Range200–1100 nm (custom)200–1100 nm
DetectorHAM S7031 1024×58 TE-CCDHAM S10141 2048×122 TE-CCD
Pixel Size12 × 12 µm
A/D Resolution18-bit18-bit
Detector CoolingTE-cooledTE-cooled (back-illuminated)
Best ForRaman, fluorescenceRaman, fluorescence, scientific
InterfaceUSB/RS232/GPIBUSB/RS232/Trigger
YSM-8105 NIR Uncooled by Yixist
NIR Uncooled · YSM-8105 Series
NIR InGaAs Spectrometers (Uncooled)

Hamamatsu InGaAs detector arrays covering 900–1700 nm. Compact optical path, replaceable slit design, and USB power make these ideal for integration into instruments for food sorting, bio-pharmaceutical analysis, laser measurement, and life science applications.

View on Yixist.com
YSM-8105 Series · 256px
YSM-8105-20
950 – 1700 nm
  • Detector: Hamamatsu G13913, 256 pixels (25×250 µm)
  • Spectral range: 950–1700 nm
  • Replaceable slit design (variable resolution/sensitivity)
  • USB powered, low power consumption
  • Compact design for system integration
  • Applications: food sorting, laser measurement
  • SDK available for secondary development
Enquire
YSM-8105 Series · 1024px ★
YSM-8105-21
950 – 1700 nm
  • Detector: Hamamatsu InGaAs, 1024 pixels (12.5×250 µm)
  • Higher resolution due to 1024-pixel array
  • Spectral range: 950–1700 nm
  • Replaceable slit system for flexible resolution
  • USB powered, very low power consumption
  • Compact; easy system integration
  • Food, bio-pharma, life science applications
Enquire
ParameterYSM-8105-20YSM-8105-21
Wavelength Range950–1700 nm950–1700 nm
DetectorHAM G13913 InGaAsHAM InGaAs
Pixels256 px (25×250 µm)1024 px (12.5×250 µm)
CoolingUncooledUncooled
Slit DesignReplaceableReplaceable
Power SupplyUSBUSB
SDK
YSM-8106 NIR TE-Cooling by Yixist
NIR TE-Cooling · YSM-8106 Series
NIR TE-Cooled InGaAs Spectrometers

Hamamatsu thermoelectrically cooled InGaAs detectors (256 or 512 pixels) for high S/N NIR spectroscopy with reduced thermal noise. Coverage from 900–2500 nm. Millisecond data acquisition speed, compact form factor, USB powered. Ideal for lab and inline process analysis.

View on Yixist.com
YSM-8106 Series · 900–1700 nm
YSM-8106-11
900 – 1700 nm · ~1 nm resolution
  • Detector: 512-pixel Hamamatsu TE-cooled InGaAs
  • Pixel size: 25×250 µm
  • Optical resolution: ~1 nm
  • High S/N ratio; low power consumption
  • Millisecond data acquisition speed
  • Replaceable slit design
  • Easy system integration
Enquire
YSM-8106 Series · 900–1700 nm
YSM-8106-12
900 – 1700 nm · 256 or 512 px
  • Detector: Hamamatsu TE-cooled InGaAs (256 or 512 px)
  • High S/N ratio; low power consumption
  • Millisecond data transmission speed
  • Compact optical path design
  • Replaceable slit for resolution adjustment
  • Lab, food, bio-pharma, life science applications
  • SDK supported; system integration ready
Enquire
YSM-8106 Series · 900–2500 nm ★
YSM-8106-18 / 8106-19
900 – 2500 nm · Full NIR coverage
  • YSM-8106-18: Hamamatsu G11478-256WB (256 px)
  • YSM-8106-19: Hamamatsu G11478-512WB (512 px)
  • Broadest NIR coverage: 900–2500 nm
  • TE-cooling for enhanced S/N ratio
  • Interchangeable slit design
  • SDK for secondary development and integration
  • Includes: USB cable, power cable, software, calibration report
Enquire
ParameterYSM-8106-11YSM-8106-12YSM-8106-18YSM-8106-19
Wavelength Range900–1700 nm900–1700 nm900–2500 nm900–2500 nm
Detector (Hamamatsu)512px TE InGaAs256 or 512px TEG11478-256WBG11478-512WB
Pixels512256 / 512256512
Resolution~1 nmCustomizableCustomizableCustomizable
CoolingTE-cooledTE-cooledTE-cooledTE-cooled
Power SupplyUSBUSBUSBUSB
YOA-8401 Portable Raman by Yixist
Raman · YOA-8401 Series
Portable Raman Spectrometers

The YOA-8401 series provides a complete Raman analysis solution in a portable 2.45 kg instrument. Built-in narrow linewidth lasers at 532 nm or 785 nm, spectral range up to 4000 cm⁻¹, and resolution better than 8 cm⁻¹. No sample preparation required — non-contact, non-destructive analysis for organic and inorganic substances.

View on Yixist.com
YOA-8401 Series · 532 nm
YOA-8401-532
176 – 3500 cm⁻¹ · 532 nm excitation
  • Excitation laser: 532 nm narrow linewidth
  • Spectral range: 176–3500 cm⁻¹
  • Resolution: < 8 cm⁻¹
  • S/N ratio: 600:1 (full range)
  • Dimensions: 342 × 180 × 89 mm · Weight: 2.45 kg
  • OEM / ODM customization supported
  • No sample pre-treatment required
Enquire
YOA-8401 Series · 785 nm ★
YOA-8401-785
176 – 3500 cm⁻¹ · 785 nm excitation
  • Excitation laser: 785 nm narrow linewidth (reduced fluorescence)
  • Spectral range: 176–3500 cm⁻¹
  • Resolution: < 8 cm⁻¹
  • S/N ratio: 600:1 (full range)
  • Dimensions: 342 × 180 × 89 mm · Weight: 2.45 kg
  • Preferred for biological samples and pharmaceuticals
  • Non-contact · non-destructive · real-time analysis
Enquire
ParameterYOA-8401-532YOA-8401-785
Excitation Wavelength532 nm785 nm
Spectral Range176–3500 cm⁻¹176–3500 cm⁻¹
Spectral Resolution< 8 cm⁻¹< 8 cm⁻¹
S/N Ratio600:1600:1
Dimensions342 × 180 × 89 mm342 × 180 × 89 mm
Weight2.45 kg2.45 kg
Fluorescence InterferenceHigher (green excitation)Lower (NIR excitation)
Best ForInorganic, minerals, polymersBiological, pharmaceutical, organic
OEM / ODM
Applications

Where Yixist spectrometers are deployed

A broad range of industries rely on Yixist instruments for quality control, research, and process monitoring.

Food & Agriculture

Sugar content, freshness, fat/protein analysis via NIR for grains, fruits, and oils.

Pharmaceuticals

Raw material identification, API quantification, tablet coating analysis, QC.

Fluorescence Spectroscopy

Emission spectra, FRET, and fluorescence lifetime measurements in biochemistry.

Raman Analysis

Molecular fingerprinting of organic and inorganic materials, counterfeit detection.

Water & Gas Monitoring

Dissolved organics, nitrates, turbidity, and trace gas concentrations in environmental samples.

Academic Research

UV-VIS-NIR spectroscopy in university physics, chemistry, and photonics labs.

Industrial QC

In-line process monitoring, colour measurement, and material sorting on production lines.

Laser Characterisation

Laser wavelength, linewidth, mode structure, and spectral purity analysis.

Enquire about Yixist spectrometers

As the authorized Malaysian distributor for Yixist, TFL Solutions can provide competitive quotations, product demonstrations, and full after-sales support. Contact us with your application requirements.